SENSUS WATER METER WIRING DIAGRAM FREE
A requirement for this application is that the pulser is in free air to ensure adequate cooling. Sensus Water & Gas Meters For Maximum Flow & Total Resolution 010: Touch-Read Filter (TRF-D) Wiring Procedures 011. In many water meter reading applications its desirable the itron ert the sensus mxu and many others. EtherMeter & PLC For Pulse-Based Batching 009: Config. EtherMeter & Koyo DL06 Comm Using Modbus/TCP, Modbus/RTU 008: Config. ¹ Usable on hot water meters up to 90 ☌ water temperature e.g. 006: Connnecting A Sensus Omni Meter (T2, C2, F2) To An EtherMeter 007: Config. Suitable for irrigation and treated waste water applications. Application The MultiRead module allows the utility to connect multiple meters to one Sensus meter reading interface device. Note: the wiring is different when connecting a Schlumberger Proread (ARB-VI) encoder to a port. Hardwire connections to either port from a compatible utility meter or MultiRead module is the same for each port. EEC directive 98/34 equal European standards EN6 Now, reading water meters can be as easy and efficient as walking or driving along the route without stopping. MXU Model 510 - Installation Wiring Diagram GENERAL INFORMATION The Model 510 MXU incorporates a two-port interface design. Transient voltage protection is highly recommended for wiring outside buildings. HRI can be retrofitted on all Sensus meters pre-equipped with an HRI modulator. Water Meter: All services are required to have a Sensus water meter with. The device will help you locate the leak. Like most water meters, sensus water meter has a leak testing device. The water meter leakage problem can happen if the installation is wrong or incorrect, a fracture on the pipe, or a damaged water meter. HRI-A3 is a special version for applications requiring a direction signal like external radio modules.ģV Lithium battery with expected lifetime 12 years.ġ.5 m - possible cable extension up to max.ģ0 m. Here are the three most common water meter problems shown by the sensus water meter problems. HRI-A4 compensates reverse flow pulses with its balanced pulse output. HRI-A and HRI-B are using the same proven pick up principle. Electronic pulse output means no switch bouncing. No magnetic detection of water direction. Load-free inductive scanning of the meter’s pointer. Can be retrofitted to pre-equipped meters The data interface can be used for M-Bus applications or for MiniBus devices like MiniPad or Sensus ( (S))cout-MB.